SunGiga G1
215 KWh
Jinko ESS SunGiga features a 215kWh liquid cooledbattery, a PCS capable of delivering up to 100kW, and anintegrated fire-fighting system all in one IP55 ratedcontainer. It's design makesinstallation in variousenvironments easy.Designed with a multi-level controlarchitecture, it is ready to meet the needs of commercial&industrial(C&l)customers, as well as provide gridancillary services.
Key Advantages
Flexible expansion
A11-in-one design with integrated PCS,reduces shipping and installation costs
Flexible multi-cabinet expansion:Modular design, support multi- cabinetparallel connection
  • A11-in-one design with integrated PCS,reduces shipping and installation costs:
  • Flexible multi-cabinet expansion:Modular design, support multi- cabinetparallel connection:
Reliable and safe
Intelligent monitoring ensures system safety
Temperature, smoke and combustiblegas sensors to detect and rapidlysuppress fire & thermal runaway events
  • Intelligent monitoring ensures system safety:
  • Temperature, smoke and combustiblegas sensors to detect and rapidlysuppress fire & thermal runaway events:
Intelligent liquid cooling
Non-uniform flow channeldesign tocontrol celltemperature difference
Multiple liquid cooling control modesto reduce system power consumption.
  • Non-uniform flow channeldesign tocontrol celltemperature difference:
  • Multiple liquid cooling control modesto reduce system power consumption.:
Smart and convenience
Remote upgrade support
Cloud-based monitoring andoperating platform supportingmultiple device access
  • Remote upgrade support:
  • Cloud-based monitoring andoperating platform supportingmultiple device access:
Applications
Commercial Buildings
Lower electricity costs through peak shaving; backup power for critical loads;
improved energy efficiency.
Lower electricity costs through peak shaving; backup power for critical loads;
improved energy efficiency.
PV-Storage-Charging Stations
Balance EV charging loads;
maximize PV self-consumption;
reduce charging costs;
prevent grid overload.
Balance EV charging loads;
maximize PV self-consumption;
reduce charging costs;
prevent grid overload.
Industrial Parks
Peak-valley arbitrage;
demand management;
uninterrupted production;
renewable energy integration.
Peak-valley arbitrage;
demand management;
uninterrupted production;
renewable energy integration.
Infrastructure
Backup power for reliable supply;
defer grid expansion;
support peak shaving and frequency regulation.
Backup power for reliable supply;
defer grid expansion;
support peak shaving
and frequency regulation.
Microgrid
Balance distributed energy fluctuations;
power critical loads during islanded operation;
improve energy self-sufficiency.
Balance distributed energy fluctuations;
power critical loads during islanded operation;
improve energy self-sufficiency.
Specifications
Battery DC parameters
Cell type LFP 3.2V/280Ah
Max. charging/discharging rate 0.5P
Cell combination method 1P240S
PACK number 5 pcs
Battery capacity 768V
Voltage range 672V~864V
Cooling method Liquid cooling
AC Parameters PCS:JKP-100LN-BA
Rated AC power 100 kW
Rated voltage 400 Vac
Rated AC Current 145A
AC side wiring method Three-phase, Four-wire
Grid voltage range 340-460 Vac
Cooling method Intelligent forced air cooling
Power factor -0.99-0.99
THD of current ≤3% (Full Load)
Current DC component ≤0.5%
Grid frequency range 50/60 Hz+ 2.5HZ
Syatem Parameters
Ambient temperature 20℃~55°℃,Derating over>45°C
Humidity ≤95%RH,no condensation
Altitude ≤2000m
Protection level IP55
Firefighting method Aerosol
Anti-corrosion grade C5 Standard
Communication interface/protocol Ethenet (LAN )/Modbus TCP
Dimension(WidthxDepthxHeight 1300x1300x2300 mm
Weight ~2800kg
Certification AS/NZS 3000, AS/NZS 3008.1.1, AS/NZS 60947.1,AS/NZS 5139:2019, Battery Best Practice Guide, CEc listed
PCS
JKP-100LN-BA (PCS) of SunGiga 215KWh all-in-one system (not to be sold separately)
AC Parameters
Rated AC Power 100kVA
AC side wiring method Three-phase, Four-wire
Cooling method Intelligent forced air cooling
Power factor -0.99-0.99
THD of current ≤3% (Full Load)
Current DC component ≤0.5%
Grid frequency range 50/60 Hz ± 2.5Hz